Testing that Reaches the World
Environmental Simulation & Product Qualification
Environmental Testing Services
Clark Testing provides environmental testing for products, components, and complete assemblies exposed to extreme temperatures, humidity, pressure changes, moisture, corrosion, sunlight, and combined operating stresses.
Our environmental laboratory supports qualification and durability programs using applicable MIL-STD-810, RTCA DO-160, IEC / EN 60068, ISO 16750, and ASTM methods. Testing is planned around the product's intended environment, specified test method, and acceptance criteria.
Laboratory Capabilities
Environmental Testing Capabilities
Environmental testing evaluates how equipment and materials respond to defined climatic and environmental exposures, including individual conditions and combinations that can accelerate degradation or reveal operational vulnerabilities.
Thermal & Climatic Testing
- High- and low-temperature exposure
- Temperature cycling and thermal shock
- Temperature and humidity cycling
- Condensation and moisture-resistance evaluations
- Heat aging and accelerated environmental exposure
Environmental Durability & Exposure
- Salt fog and corrosion testing, including ASTM B117 where specified
- UV exposure, weathering, fading, and material degradation
- Rain, water spray, drip, immersion, and IP-related water ingress testing
- Sand and dust exposure
- Fungus and fluid contamination methods when specified
Altitude & Combined Environments
- Low-pressure and altitude simulation
- Temperature, humidity, vibration, and altitude combinations
- Environmental stress screening (ESS)
- Freeze/thaw exposure
- Custom environmental test-program development
Related capabilities: Coordinate environmental exposure with vibration testing, environmental aging, failure analysis, and analytical chemistry when the qualification program calls for multiple disciplines.
Military Environmental Qualification
MIL-STD-810 Environmental Testing Methods
The existing Clark Testing environmental page identifies the following MIL-STD-810 methods. The applicable procedure, severity, duration, test configuration, and acceptance criteria depend on the contract, product life-cycle profile, and specified revision.
| MIL-STD-810 method | Test category | Evaluation focus |
|---|---|---|
| Method 500 | Low Pressure (Altitude) | Reduced-pressure operation, storage, and transport |
| Method 501 | High Temperature | Elevated-temperature exposure and performance |
| Method 502 | Low Temperature | Cold-temperature exposure and performance |
| Method 503 | Temperature Shock | Rapid changes between temperature conditions |
| Method 504 | Contamination by Fluids | Exposure to specified fluids and associated effects |
| Method 506 | Rain | Rainfall, blowing rain, and water exposure as specified |
| Method 507 | Humidity | Humidity and moisture-related effects |
| Method 508 | Fungus | Fungal growth susceptibility under specified conditions |
| Method 509 | Salt Fog | Corrosive salt-laden atmospheric exposure |
| Method 510 | Sand and Dust | Particulate exposure and intrusion |
| Method 512 | Immersion | Immersion and leakage resistance |
| Method 520 | Temperature, Humidity, Vibration, Altitude | Combined environmental exposure |
| Method 524 | Freeze / Thaw | Freezing, thawing, and related moisture effects |
| Method 525 | Time Waveform Replication | Replication of specified time-history inputs |
Listing a method does not establish that every procedure or revision is available, applicable to every product, or included in the laboratory's accredited scope. Confirm the requested revision and detailed test profile during quotation.
Thermal & Climatic Exposure
Thermal, Humidity and Environmental Chamber Testing
High- and Low-Temperature Testing
Temperature testing evaluates functional performance, material behavior, and durability at specified hot and cold conditions. Programs may involve operating and non-operating exposures, temperature cycling, heat aging, and examination of expansion or compatibility concerns. For specific military environmental procedures, see MIL-STD-810 Method 501 High Temperature and Method 502 Low Temperature.
Temperature and Humidity Cycling
Controlled humidity and temperature-humidity cycling help assess moisture ingress, condensation, corrosion susceptibility, insulation changes, and performance during changing environmental conditions. Learn more about Clark Testing's Humidity testing.
Thermal Shock and Rapid Transitions
Thermal shock testing exposes a specimen to rapid temperature transitions to reveal failures associated with differential expansion, seals, joints, interfaces, electronics, and other temperature-sensitive features. See the dedicated MIL-STD-810 Method 503 Temperature Shock Testing page for method-specific information.
Environmental Chambers and Test Setup
The source page describes environmental chambers supporting extreme temperature conditions, controlled humidity, rapid temperature transitions, and large assemblies, with multi-voltage and frequency configurations and integrated multi-condition testing. Exact chamber dimensions, operating ranges, ramp rates, and available configurations should be confirmed for each project. Learn more about Clark Testing's Environmental testing equipment and chambers.
Durability & Exposure
Corrosion, Weathering, Ingress and Contamination Testing
Salt Spray and Salt Fog Corrosion
Salt spray and salt fog exposure can help evaluate coating performance, corrosion resistance, and the effects of saline environments on materials and assemblies. Environmental aging testing may complement corrosion programs. ASTM B117 is one common salt spray reference, but pass/fail criteria must come from the applicable product specification. Learn more about Clark Testing's Salt spray testing. See also our corrosion testing services.
UV Exposure and Weathering
UV and weathering programs examine changes associated with light exposure, including fading, color stability, surface degradation, and material durability. Exposure conditions and evaluation criteria should reflect the applicable method.
Rain, Water Ingress and Immersion
Water-exposure programs may include rain, spray, drip, and immersion tests to assess enclosure integrity and equipment performance. IP water-protection evaluations must be matched to the exact requested IP designation and applicable standard; a water test alone does not establish an overall IP rating. Learn more about Clark Testing's Ingress protection (IP) testing. The original environmental page also references Clark Testing's Ingress Protection service overview.
Sand, Dust, Fungus and Fluid Contamination
Additional environmental exposures identified in the source include particulate intrusion, fungal growth susceptibility, and contamination by specified fluids. Selection depends on the anticipated service environment and test article materials.
Specialized Test Programs
Altitude, Combined Environments and ESS
Altitude and Low-Pressure Simulation
Reduced-pressure testing simulates altitude-related conditions for aerospace, high-elevation, and transportation applications. Depending on the specification, the program may address operation, storage, or transport at defined pressure conditions. Learn more about Clark Testing's Altitude testing services.
Combined Temperature, Humidity, Vibration and Altitude
Combined-environment testing can reveal failure modes that are not apparent when stresses are applied separately. The source identifies temperature, humidity, vibration, and altitude combinations, as well as environmental stress screening and multi-condition simulation. Confirm which combinations and configurations can be performed together for the specific specimen. For military combined-environment programs, see MIL-STD-810 Method 520.
Custom Test Profiles and Environmental Stress Screening
Programs may be tailored around defined operating environments, customer specifications, environmental stress screening objectives, and product qualification requirements. A representative test profile should identify exposure levels, duration, operating modes, monitoring, and acceptance criteria.
Standards & Methods
Environmental Testing Standards and Applications
The following references appeared in the source page or are directly related to its named methods. Not every method is appropriate for every product, and specific editions and procedures should be confirmed before testing.
| Standard or family | Typical application | Environmental focus |
|---|---|---|
| MIL-STD-810 | Military equipment environmental engineering | Temperature, pressure, rain, humidity, salt fog, sand/dust, immersion and combined methods |
| RTCA DO-160 | Airborne equipment environmental qualification | Applicable environmental categories and procedures |
| IEC / EN 60068 series | Environmental testing of electrotechnical products | Cold, dry heat, damp heat, temperature change and other selected exposures |
| ISO 16750 series | Road-vehicle electrical and electronic equipment | Environmental conditions and testing for automotive applications |
| ASTM B117 | Corrosion testing of materials and coatings | Salt spray (fog) apparatus operation |
| Applicable IP / ingress specifications | Enclosure protection evaluation | Water exposure and ingress criteria as specified |
For official method selection and standard editions, consult DLA ASSIST for military specifications and ASTM International for ASTM standards. Confirm project-specific revisions and any required accreditation scope with Clark Testing.
Test Planning
Preparing an Environmental Qualification Program
Define the Operating Environment
Identify the intended installation, transport, storage, and operational environments, including temperature extremes, moisture, salt exposure, altitude, dust, and expected combined stresses.
Specify the Standard and Acceptance Criteria
Provide the required standard and revision, method and procedure, severity, exposure duration, functional operating modes, and acceptance criteria. MIL-STD-810 methods in particular must be tailored to the equipment and its life-cycle environmental profile.
Plan Specimen Monitoring and Documentation
Confirm specimen size and mass, electrical and mechanical interfaces, power requirements, instrumentation, test-fixture needs, monitoring during exposure, and required reporting. Coordinated programs may also use vibration testing and failure analysis.
Common Questions
Environmental Testing FAQs
What is environmental testing?
Environmental testing exposes a product or material to specified climatic or environmental conditions to evaluate performance, durability, or compliance with a defined test method.
Does Clark Testing support MIL-STD-810 environmental testing?
The existing environmental service source identifies methods 500, 501, 502, 503, 504, 506, 507, 508, 509, 510, 512, 520, 524, and 525. Availability of particular procedures, revisions, combined setups, and accredited methods should be confirmed during planning.
What is the difference between temperature cycling and thermal shock?
Temperature cycling evaluates performance through repeated temperature changes, while thermal shock focuses on relatively rapid transitions that can stress dissimilar materials, seals, joints, and components.
Can environmental stresses be combined in one test?
Some programs combine temperature, humidity, vibration, or altitude. Feasibility depends on specimen dimensions, fixtures, required conditions, equipment configuration, and the test specification.
Does salt spray testing establish a product service life?
No. Salt spray exposure provides a controlled comparative or qualification condition, but a specified number of test hours does not by itself predict real-world service life.
What information is needed for a quote?
Share the product description, dimensions and weight, applicable standards and revisions, methods and procedures, environmental severity and duration, operating modes, required monitoring, acceptance criteria, and project schedule.
Work with Clark Testing
Plan Your Environmental Test Program
Tell us about your product, operating environment, required standards, exposure conditions, and qualification goals. We can help evaluate the appropriate environmental testing approach.