Environmental Testing Equipment & Capabilities
Clark Testing offers a comprehensive range of environmental testing equipment designed to simulate real-world conditions and validate product performance. Our chambers support a wide range of temperature, humidity, and environmental conditions to meet diverse testing requirements.
Walk-In Environmental Chambers
ESPEC Walk-In Chamber
- Temperature Range: -70°C to 95°C
- Maximum Cooling Ramp: 5°C/minute with 10,000 lb load
- Humidity Range: 15% to 95% RH (within measurable tolerance)
- Entryway: 8 ft (W) x 10 ft (H)
- Internal Test Area: 16 ft (W) x 16 ft (D)
- Access Ports: (4) 4-inch ports
Russells Walk-In Chamber
- Temperature Range: -30°C (-90°C LN2 Assist) to 95°C
- Humidity Range: 15% to 95% RH (within measurable tolerance)
- Entryway: 72 in (W) x 95.5 in (H) (6 ft x 7.9 ft)
- Internal Test Area: 146 in (W) x 183 in (D) x 121 in (H) (12 ft x 15 ft x 10 ft)
- Access Ports: (3) 6-inch ports
Environmental Test Chambers
Russells High Altitude Chamber
- Temperature Range: -30°C to 175°C
- Cooling Ramp: 2°C/minute
- Humidity Range: 15% to 95% RH (within measurable tolerance)
- Internal Test Area: 72 in (W) x 42 in (D) x 60 in (H)
- Access Port: (1) 3-inch port
- Capacity: 350 lbs
Thermotron Cabinet Chamber (Model 1)
- Temperature Range: 0°C to 95°C
- Cooling Ramp: 2°C/minute
- Humidity Range: 15% to 95% RH (within measurable tolerance)
- Internal Test Area: 36 in (W) x 36 in (D) x 36 in (H)
- Access Ports: (2) 6-inch ports
Thermotron Cabinet Chamber (Model 2)
- Temperature Range: -70°C to 170°C
- Cooling Ramp: 10°C/minute
- Internal Test Area: 24 in (W) x 24 in (D) x 24 in (H)
- Access Ports: (2) 4-inch ports
High Temperature Ovens
Grieve High Temperature Oven
- Temperature Range: Ambient to 400°C
- Units Available: 4 (various sizes and capabilities)
- Maximum Internal Test Area: 47 in (W) x 47 in (D) x 72 in (H)
- Access Port: (1) 3-inch port
Summary of Capabilities
Clark Testing’s environmental testing equipment supports:
- Extreme temperature cycling and thermal shock conditions
- Humidity-controlled environments
- Large-scale and high-load testing applications
- High-altitude and pressure simulation
- High-temperature material and component validation