Testing that Reaches the World
Equipment Reliability & Laboratory Analysis
Condition Monitoring Testing Services
Clark Testing's Condition Monitoring Services (CMS) Laboratory provides oil analysis and diagnostics to help maintenance teams recognize equipment wear, fluid contamination, and lubricant degradation before they lead to unplanned downtime.
Our CMS Lab evaluates oil, water-glycol fluids, and grease for condition-based maintenance, incoming lubricant quality assurance, and machinery reliability programs. Results can help guide maintenance schedules, lubricant changes, and investigation of developing equipment problems.
Laboratory Capabilities
Condition Monitoring and Oil Analysis Capabilities
Our CMS Lab analyzes samples from operating machinery and incoming lubricants, providing test data and diagnostic information to support maintenance decisions.
Lubricant Health & Contamination
- Lubricant degradation and remaining service-life evaluation
- Viscosity, acid number, base number, and infrared analysis
- Water contamination and particle cleanliness evaluation
- Recycled and reclaimed lubricant evaluation
- Oil, water-glycol, and grease analysis
Wear & Reliability Diagnostics
- Elemental additive depletion and wear-metal analysis
- Wear debris diagnostics and optical ferrography
- Ferrous particle quantification and wear index
- Lubricant quality assurance and maintenance trend monitoring
- Diagnostic reporting and maintenance recommendations
Related laboratory services: Explore Fuel & Lubrication Testing and Analytical Chemistry for complementary fluid and material analysis. The appropriate test package depends on equipment and fluid requirements.
Condition-Based Maintenance
Oil Analysis for Predictive Maintenance
Routine oil sampling can help identify changes in lubricant condition, contamination levels, and machine wear. Comparing results over time is often more useful than interpreting a single sample in isolation. Clark Testing's CMS Laboratory supports maintenance professionals with laboratory testing, reporting, and recommendations intended to help identify developing problems and plan service interventions.
Lubricant Condition
Viscosity, acid and base numbers, infrared spectroscopy, and other fluid properties can indicate changes associated with oxidation, additive depletion, contamination, or improper fluid selection.
Equipment Wear
Wear metals, particle counts, optical ferrography, and ferrous particle measurements provide different views of wear debris and contamination. Selection depends on the equipment, fluid, and suspected failure mode.
Application-Specific Monitoring
CMS Test Packages and Equipment Applications
The existing Clark Testing CMS program includes testing packages for agriculture, trucking and transportation, construction, mining, and forestry equipment. The links below preserve the dedicated equipment-specific testing pages.
- Agriculture: equipment-specific oil analysis and maintenance monitoring applications
- Trucking & Transportation: equipment-specific oil analysis and maintenance monitoring applications
- Construction: equipment-specific oil analysis and maintenance monitoring applications
- Mining: equipment-specific oil analysis and maintenance monitoring applications
- Forestry: equipment-specific oil analysis and maintenance monitoring applications
Testing packages can be tailored to the machinery, lubricant type, operating environment, sample history, and maintenance objectives. Ask the laboratory to confirm the current package contents and sample requirements.
Testing Methods
Condition Monitoring Tests and Standards
These are the existing CMS page's linked test methods, retained as direct links to Clark Testing's individual testing-standard and service pages. Test applicability varies by fluid type, equipment, and diagnostic objective.
| Linked test / method | What it evaluates |
|---|---|
| ASTM D974 | Acid Number |
| ASTM E2412 | Infrared Organic Spectrometry (FTIR) |
| ASTM D1293 | pH of Fluid Sample |
| ASTM D445 | Viscosity, Kinematic (40C, 100C, Visc Index) |
| ASTM D1121 | Reserve Alkalinity |
| ASTM D5984 | Base Number |
| Particle Cleanliness (ISO, SAE, or NAS Codes) | ISO 4406 |
| ASTM D6595 | Spectrometric Analysis (21 metals) |
| ASTM D6304 | Water by Karl Fischer Titration |
| ASTM D7042 | Density |
Additional CMS Diagnostics
- Wear Debris Analysis (WDA) using optical ferrography
- Wear Index using a ferrous particle quantifier (PQ-90)
- Varnish potential evaluation
For particle contamination, see Clark Testing's existing Particle Cleanliness / Particle Count service link. Consult the laboratory for the applicable cleanliness code and reporting method.
Program Development
What to Include in a Condition Monitoring Program
When requesting a test program, identify the equipment and component, lubricant manufacturer and grade, operating hours, service conditions, sample location, maintenance history, and any suspected symptoms. Establish consistent sampling intervals and locations so that trends can be interpreted meaningfully.
Clark Testing's existing CMS offering includes quality assurance programs, service-life evaluation, diagnosis, and maintenance recommendations. Lab data should be considered alongside operating conditions, inspection findings, and equipment manufacturer guidance.
Technical Reference
Condition Monitoring Method Resources
Test procedures and revisions are published by organizations such as ASTM International. The linked Clark Testing method pages above provide a useful starting point for selecting a laboratory test; confirm the method revision, sample volume, and suitability with our team.
Common Questions
Condition Monitoring FAQs
What does condition monitoring oil analysis detect?
Oil analysis can identify lubricant property changes, contaminants, wear metals, and wear debris. Interpreting trends can help maintenance teams recognize developing equipment issues.
Does Clark Testing analyze more than engine oil?
Yes. The existing CMS Lab description includes oil, water-glycol fluids, and grease analysis. The exact tests available depend on the sample and fluid type.
What is the difference between wear-metal testing and particle counting?
Elemental analysis measures metals present in the sample, while particle counting assesses the concentration of particles by size or cleanliness category. Wear debris analysis can provide additional information about particle morphology and wear mechanisms.
Can CMS testing support equipment-specific maintenance programs?
Yes. Clark Testing maintains dedicated application pages for agricultural, trucking, construction, mining, and forestry equipment, and can review test selection against your equipment and maintenance objectives.
What information should I provide for a CMS testing quote?
Provide the equipment type, fluid type and grade, operating hours, known maintenance concerns, sample count, requested methods or package, and reporting requirements.
Work with Clark Testing
Discuss Your Condition Monitoring Program
Whether you need routine oil analysis, wear debris diagnostics, lubricant quality assurance, or an equipment-specific CMS test package, our team can help review the right approach.