Request a Quote
Superior

Testing that Reaches the World

Clark Testing | Structural Load & Fatigue Testing

Anchors, Tie-Downs, Fasteners, Screws & Bolts Testing

Independent structural testing of anchoring and fastening systems for load capacity, durability and performance under demanding service conditions.

Structural Testing Capabilities

Testing Fasteners for Real-World Loads

Clark Testing's Structures Lab evaluates anchors, tie-downs, screws, bolts and specialty fastening hardware for structural performance and durability.

Our structural load and fatigue testing supports construction, infrastructure, aerospace and industrial applications. Testing programs can simulate application-specific conditions to characterize load resistance, repeated-load performance and failure behavior.

Test methods and acceptance criteria are selected based on the product, applicable specification and project scope. Clark Testing's Structures Lab operates within an ISO/IEC 17025-accredited laboratory program; confirm specific accredited methods and scope for your project.

Hardware & Assemblies

Anchors and Fastening Systems We Test

Mechanical Anchors

Evaluate installed mechanical anchors for tensile, shear and other specified loading conditions.

Concrete & Masonry Anchors

Test anchoring systems used in concrete and masonry substrates under applicable test procedures.

Structural Screws & Lag Bolts

Characterize load resistance and performance of screws and lag bolts in specified assemblies.

Tie-Down & Restraint Systems

Evaluate hardware used for seismic restraint, wind uplift and shear-resisting applications.

High-Tension Bolts & Fasteners

Assess structural fasteners under defined load and fatigue requirements.

Custom & Specialty Hardware

Develop project-specific testing approaches for proprietary fasteners and assemblies.

Laboratory & Field Methods

Structural Load, Fatigue and Durability Testing

Tensile & Pull-Out Testing

Determine axial load resistance and pull-out performance under defined installation and loading conditions.

Shear Testing

Measure resistance to lateral loads and document load-displacement or failure behavior as specified.

Cyclic Load Testing

Assess response to repeated loading representative of the intended application.

Ultimate Load & Fatigue Testing

Apply specified loads or load to failure to evaluate strength and fatigue performance.

Creep & Sustained-Load Testing

Evaluate deformation and performance over time under sustained loads.

Environmental Conditioning

Expose hardware to specified temperature, humidity or corrosion conditions before or during evaluation.

Field Load Testing

Perform on-site verification of installed fastening systems under agreed test conditions.

Applicable Specifications

ASTM, ACI, ICC-ES and Project-Specific Requirements

Clark Testing identifies the following standards and criteria among the references used to plan anchor and fastener testing. Applicability depends on anchor type, substrate, installation details and the edition required by the project.

ASTM E488 / E488M

Test methods for strength of anchors in concrete elements.

ASTM E1512

Referenced by Clark Testing for anchor testing; confirm the applicable scope and edition for your specific application.

ICC-ES AC193, AC106 & AC233

Acceptance criteria that may be relevant to specific anchor and fastener product evaluations.

ACI 355.2 & ACI 355.4

Qualification requirements for applicable post-installed mechanical and adhesive anchors in concrete.

ISO, EN & CSA Specifications

International and regional requirements considered where applicable to the product and market.

Custom Test Specifications

Proprietary requirements and project-specific loading protocols for specialized hardware.

Important: A test performed using a referenced standard does not, by itself, establish product certification or code approval. Discuss required acceptance criteria, evaluation reports and accreditation scope when requesting testing.

Applications

Industries That Depend on Reliable Fasteners

Defense & Aerospace

Fastening systems for demanding structural and equipment applications.

Commercial & Residential Construction

Anchors and connectors used in building systems and structural assemblies.

Seismic & Wind-Resistant Design

Tie-down and restraint hardware subject to seismic, uplift and shear demands.

Bridges & Infrastructure

Structural fastening solutions for transportation and civil infrastructure.

Rail & Marine Transportation

Hardware subjected to vibration, repeated loading and environmental exposure.

Renewable Energy

Anchors and fastening systems for solar installations, wind foundations and related structures.

Manufacturing & R&D

Prototype validation, product comparisons and custom hardware development.

Project Planning

What to Include in a Fastener Testing Request

To define a suitable test program, provide drawings or product specifications, hardware material and dimensions, substrate or mounting details, installation procedure, expected load directions, relevant standards, environmental conditions, sample quantities and required acceptance criteria. If a field installation is involved, include site access and configuration details.

These inputs help establish the test fixture, instrumentation, loading protocol and reporting requirements before work begins.

Common Questions

Anchor and Fastener Testing FAQs

What is anchor pull-out testing?

Pull-out testing applies a tensile load to an installed anchor to characterize its resistance to axial loading under specified conditions.

Can you test anchors in concrete and masonry?

Yes. Clark Testing identifies concrete and masonry anchors among its structural testing capabilities. The applicable procedure depends on the anchor, substrate and specification.

What is the difference between tensile and shear testing?

Tensile testing applies force along the anchor axis, while shear testing applies lateral force. Some projects require both loading directions.

Can fasteners be tested under cyclic or sustained loads?

Clark Testing lists cyclic, fatigue, creep and long-term load evaluations among its available structural test approaches.

Do you test to ASTM E488 or ACI 355 requirements?

These references are included in Clark Testing's published anchor-testing scope. Confirm the relevant standard edition, acceptance criteria and accredited test scope for the project.

Can custom tie-downs or proprietary fasteners be evaluated?

Yes. Provide drawings, installation details and the proposed loading or performance requirements so the laboratory can assess a suitable test plan.

Structural Testing Support

Request Anchor & Fastener Testing

Discuss your anchors, bolts, screws, tie-down systems or specialty hardware with Clark Testing. We can review your test objectives, applicable specifications and project requirements.

We work closely with you to validate engineering, ensure quality, analyze products and qualify equipment while supporting the time constraints and product cycles that are vital to your success.

Paul Heffernan, CEO of Clark Testing