Testing that Reaches the World
Clark Testing | Structural Load & Fatigue Testing
Anchors, Tie-Downs, Fasteners, Screws & Bolts Testing
Independent structural testing of anchoring and fastening systems for load capacity, durability and performance under demanding service conditions.
Structural Testing Capabilities
Testing Fasteners for Real-World Loads
Clark Testing's Structures Lab evaluates anchors, tie-downs, screws, bolts and specialty fastening hardware for structural performance and durability.
Our structural load and fatigue testing supports construction, infrastructure, aerospace and industrial applications. Testing programs can simulate application-specific conditions to characterize load resistance, repeated-load performance and failure behavior.
Test methods and acceptance criteria are selected based on the product, applicable specification and project scope. Clark Testing's Structures Lab operates within an ISO/IEC 17025-accredited laboratory program; confirm specific accredited methods and scope for your project.
Hardware & Assemblies
Anchors and Fastening Systems We Test
Mechanical Anchors
Evaluate installed mechanical anchors for tensile, shear and other specified loading conditions.
Concrete & Masonry Anchors
Test anchoring systems used in concrete and masonry substrates under applicable test procedures.
Structural Screws & Lag Bolts
Characterize load resistance and performance of screws and lag bolts in specified assemblies.
Tie-Down & Restraint Systems
Evaluate hardware used for seismic restraint, wind uplift and shear-resisting applications.
High-Tension Bolts & Fasteners
Assess structural fasteners under defined load and fatigue requirements.
Custom & Specialty Hardware
Develop project-specific testing approaches for proprietary fasteners and assemblies.
Laboratory & Field Methods
Structural Load, Fatigue and Durability Testing
Tensile & Pull-Out Testing
Determine axial load resistance and pull-out performance under defined installation and loading conditions.
Shear Testing
Measure resistance to lateral loads and document load-displacement or failure behavior as specified.
Cyclic Load Testing
Assess response to repeated loading representative of the intended application.
Ultimate Load & Fatigue Testing
Apply specified loads or load to failure to evaluate strength and fatigue performance.
Creep & Sustained-Load Testing
Evaluate deformation and performance over time under sustained loads.
Environmental Conditioning
Expose hardware to specified temperature, humidity or corrosion conditions before or during evaluation.
Field Load Testing
Perform on-site verification of installed fastening systems under agreed test conditions.
Applicable Specifications
ASTM, ACI, ICC-ES and Project-Specific Requirements
Clark Testing identifies the following standards and criteria among the references used to plan anchor and fastener testing. Applicability depends on anchor type, substrate, installation details and the edition required by the project.
ASTM E488 / E488M
Test methods for strength of anchors in concrete elements.
ASTM E1512
Referenced by Clark Testing for anchor testing; confirm the applicable scope and edition for your specific application.
ICC-ES AC193, AC106 & AC233
Acceptance criteria that may be relevant to specific anchor and fastener product evaluations.
ACI 355.2 & ACI 355.4
Qualification requirements for applicable post-installed mechanical and adhesive anchors in concrete.
ISO, EN & CSA Specifications
International and regional requirements considered where applicable to the product and market.
Custom Test Specifications
Proprietary requirements and project-specific loading protocols for specialized hardware.
Important: A test performed using a referenced standard does not, by itself, establish product certification or code approval. Discuss required acceptance criteria, evaluation reports and accreditation scope when requesting testing.
Applications
Industries That Depend on Reliable Fasteners
Defense & Aerospace
Fastening systems for demanding structural and equipment applications.
Commercial & Residential Construction
Anchors and connectors used in building systems and structural assemblies.
Seismic & Wind-Resistant Design
Tie-down and restraint hardware subject to seismic, uplift and shear demands.
Bridges & Infrastructure
Structural fastening solutions for transportation and civil infrastructure.
Rail & Marine Transportation
Hardware subjected to vibration, repeated loading and environmental exposure.
Renewable Energy
Anchors and fastening systems for solar installations, wind foundations and related structures.
Manufacturing & R&D
Prototype validation, product comparisons and custom hardware development.
Project Planning
What to Include in a Fastener Testing Request
To define a suitable test program, provide drawings or product specifications, hardware material and dimensions, substrate or mounting details, installation procedure, expected load directions, relevant standards, environmental conditions, sample quantities and required acceptance criteria. If a field installation is involved, include site access and configuration details.
These inputs help establish the test fixture, instrumentation, loading protocol and reporting requirements before work begins.
Common Questions
Anchor and Fastener Testing FAQs
What is anchor pull-out testing?
Pull-out testing applies a tensile load to an installed anchor to characterize its resistance to axial loading under specified conditions.
Can you test anchors in concrete and masonry?
Yes. Clark Testing identifies concrete and masonry anchors among its structural testing capabilities. The applicable procedure depends on the anchor, substrate and specification.
What is the difference between tensile and shear testing?
Tensile testing applies force along the anchor axis, while shear testing applies lateral force. Some projects require both loading directions.
Can fasteners be tested under cyclic or sustained loads?
Clark Testing lists cyclic, fatigue, creep and long-term load evaluations among its available structural test approaches.
Do you test to ASTM E488 or ACI 355 requirements?
These references are included in Clark Testing's published anchor-testing scope. Confirm the relevant standard edition, acceptance criteria and accredited test scope for the project.
Can custom tie-downs or proprietary fasteners be evaluated?
Yes. Provide drawings, installation details and the proposed loading or performance requirements so the laboratory can assess a suitable test plan.
Structural Testing Support
Request Anchor & Fastener Testing
Discuss your anchors, bolts, screws, tie-down systems or specialty hardware with Clark Testing. We can review your test objectives, applicable specifications and project requirements.