Testing that Reaches the World
Environmental Simulation & Low-Pressure Testing
Altitude Testing Services
Clark Testing evaluates product performance, durability and functionality in simulated high-altitude, low-pressure environments using an altitude chamber capable of simulating conditions up to 50,000 feet.
Support for aerospace, defense, electronics, packaging and transportation applications, including test programs based on applicable MIL-STD-810, ASTM D6653 and IEC 60068-2-13 requirements.
Laboratory Capabilities
Altitude Chamber Specifications
The chamber simulates low-pressure conditions encountered during air transport and operation at high elevations. The following specifications are reported on Clark Testing's existing altitude service page.
- Altitude simulation: Sea level to 50,000 feet
- Temperature control: -30°F to +177°C; reported ±1°C stability
- Humidity control: 20% to 95% relative humidity
- Interior dimensions: 72 in. W × 48 in. D × 60 in. H
- Data acquisition: Real-time pressure, temperature and humidity monitoring and reporting
Why Low Pressure Matters
Evaluate Pressure-Related Product Risks
Reduced atmospheric pressure can affect sealed enclosures, packaging, adhesives, electrical systems and mechanical assemblies. Simulated altitude testing helps identify pressure-related failure modes before products are shipped or deployed.
Depending on the test plan, evaluations may support product validation, failure investigation and documentation of performance under specified low-pressure conditions.
Testing Applications
What Altitude Testing Helps Evaluate
Air Transport & Packaging
Assess package integrity and sealed systems exposed to reduced pressure during air cargo transport.
Electronics & Power Systems
Evaluate circuit boards, sensors, batteries and other assemblies intended to operate or travel at elevation.
Aerospace & Defense Components
Investigate the response of avionics, payload systems and related equipment to specified altitude environments.
Medical Device Packaging
Assess the physical integrity of packaged medical devices during simulated high-altitude transport; sterility assurance requires its own appropriate validation program.
Applicable Test Methods
Altitude Testing Standards
Clark Testing's original altitude page identifies the following standards. The required revision, procedure, test conditions and acceptance criteria should be confirmed for each project.
MIL-STD-810 Method 500, Low Pressure (Altitude)
Military environmental test method for low-pressure exposures associated with storage, transportation and operation.
ASTM D6653
Evaluates effects of high altitude on packaging systems by vacuum method.
IEC 60068-2-13
Environmental testing procedure addressing low air pressure.
Testing to a named method is not the same as a blanket product certification. Confirm the laboratory's current accredited scope for the specific method when accreditation is required.
Coordinated Environmental Programs
Altitude, Temperature & Humidity Considerations
Altitude exposure can be evaluated alongside thermal and humidity requirements where the equipment's intended environment and the selected procedure call for them. Test sequencing and combined conditions should be established in the approved test plan rather than assumed to apply to every product.
For broader environmental qualification, see Environmental Aging & Life Cycle Testing and MIL-STD-810 Environmental Testing.
Planning Your Program
Information Needed for an Altitude Testing Quote
To scope a suitable test program, provide the product's dimensions and weight, required standard and revision, simulated altitude or pressure profile, exposure duration, temperature and humidity requirements, operating configuration, instrumentation needs and pass/fail criteria.
Our team can review these inputs and discuss a test approach aligned with your application and reporting needs.
Frequently Asked Questions
Altitude Testing FAQs
How high can Clark Testing's altitude chamber simulate?
The existing altitude service page lists a simulated altitude range from sea level to 50,000 feet.
What kinds of failures can low-pressure testing reveal?
Depending on the product, testing may reveal packaging deformation, seal problems, expansion effects or changes in electrical and mechanical performance.
Does altitude testing always include temperature and humidity cycling?
No. The exposure profile depends on the applicable method and the customer's requirements. Additional environmental conditions should be specified in the test plan.
Which altitude testing standards are referenced?
Clark Testing's original service description references MIL-STD-810 Method 500.6, ASTM D6653 and IEC 60068-2-13. Confirm the revision required by your program.
What should I provide to request a quote?
Share the equipment dimensions, required test method, altitude profile, duration, operating conditions and acceptance criteria.
Altitude & Low-Pressure Testing
Ready to Evaluate Your Product at Altitude?
Send your specifications and required pressure profile. Clark Testing can discuss chamber fit, test requirements and next steps.