Request a Quote
Clark Testing

Laboratory Equipment | Environmental Testing

Environmental Testing Equipment & Capabilities

Explore Clark Testing’s walk-in environmental chambers, cabinet chambers, high-altitude chamber and high-temperature ovens. Our equipment supports controlled temperature, humidity and environmental simulation for product and component validation.

Environmental Test Chamber Capabilities

Clark Testing offers a range of environmental testing equipment designed to simulate real-world conditions and evaluate product performance. Equipment selection depends on specimen dimensions, loading, temperature profiles and environmental requirements.

Laboratory Capabilities

Environmental Conditions We Simulate

  • Extreme temperature cycling and thermal shock conditions
  • Humidity-controlled environments
  • Large-scale and high-load testing applications
  • High-altitude and pressure simulation
  • High-temperature material and component validation

Confirm the required combination of temperature, humidity, ramp rate and specimen load with our laboratory before scheduling testing.

Walk-In Environmental Chambers

ESPEC Walk-In Chamber

  • Temperature Range: -70°C to 95°C
  • Maximum Cooling Ramp: 5°C/minute with 10,000 lb load
  • Humidity Range: 15% to 95% RH (within measurable tolerance)
  • Entryway: 8 ft (W) x 10 ft (H)
  • Internal Test Area: 16 ft (W) x 16 ft (D)
  • Access Ports: (4) 4-inch ports

Russells Walk-In Chamber

  • Temperature Range: -30°C (-90°C LN2 Assist) to 95°C
  • Humidity Range: 15% to 95% RH (within measurable tolerance)
  • Entryway: 72 in (W) x 95.5 in (H) (6 ft x 7.9 ft)
  • Internal Test Area: 146 in (W) x 183 in (D) x 121 in (H) (12 ft x 15 ft x 10 ft)
  • Access Ports: (3) 6-inch ports

Environmental Test Chambers

Russells High Altitude Chamber

  • Temperature Range: -30°C to 175°C
  • Cooling Ramp: 2°C/minute
  • Humidity Range: 15% to 95% RH (within measurable tolerance)
  • Internal Test Area: 72 in (W) x 42 in (D) x 60 in (H)
  • Access Port: (1) 3-inch port
  • Capacity: 350 lbs

Thermotron Cabinet Chamber (Model 1)

  • Temperature Range: 0°C to 95°C
  • Cooling Ramp: 2°C/minute
  • Humidity Range: 15% to 95% RH (within measurable tolerance)
  • Internal Test Area: 36 in (W) x 36 in (D) x 36 in (H)
  • Access Ports: (2) 6-inch ports

Thermotron Cabinet Chamber (Model 2)

  • Temperature Range: -70°C to 170°C
  • Cooling Ramp: 10°C/minute
  • Internal Test Area: 24 in (W) x 24 in (D) x 24 in (H)
  • Access Ports: (2) 4-inch ports

High Temperature Ovens

Grieve High Temperature Oven

  • Temperature Range: Ambient to 400°C
  • Units Available: 4 (various sizes and capabilities)
  • Maximum Internal Test Area: 47 in (W) x 47 in (D) x 72 in (H)
  • Access Port: (1) 3-inch port

Related Testing Services

Frequently Asked Questions

How large are the walk-in environmental chambers?

The ESPEC chamber has a 16 ft wide by 16 ft deep internal test area. The Russells walk-in chamber has an internal area of 146 x 183 x 121 inches (W x D x H).

What is the maximum oven temperature?

The Grieve high-temperature ovens operate from ambient temperature to 400°C. Four units are available in various sizes and capabilities.

Can Clark Testing accommodate heavy test specimens?

The ESPEC walk-in chamber has a specified maximum cooling ramp of 5°C/minute with a 10,000 lb load. Contact the laboratory to confirm suitability for your specimen and test profile.

Discuss Your Environmental Testing Requirements

Provide your specimen dimensions, weight, environmental conditions and applicable test requirements so our team can help identify suitable equipment.