Request a Quote
Superior

Testing that Reaches the World

FM 1950 – Seismic Sway Brace Testing for Pipe, Tubing and Conduit

FM 1950 Seismic Sway Brace Component Testing

FM 1950 establishes design and performance requirements for rigid seismic sway brace components used to restrain pipe, tubing, and conduit against earthquake-related movement.

Seismic sway bracing plays an important role in protecting piping systems and their connections during earthquakes. Properly designed and evaluated brace components help transfer seismic forces between supported piping and building structures, reducing the risk of excessive movement or component failure.

Clark Testing provides structural, mechanical, and seismic testing services to support manufacturers evaluating sway brace components, mounting hardware, and equipment restraint systems.

What Is FM 1950?

FM 1950, Seismic Sway Braces for Pipe, Tubing and Conduit, is an FM Approvals standard establishing criteria for rigid seismic sway brace components and assemblies.

The standard addresses components used to connect piping, tubing, and conduit restraint systems to building structural elements.

These components can include:

  • Building-attached sway brace fittings
  • Pipe-attached brace components
  • Mechanical connectors and attachment assemblies
  • Rigid seismic bracing hardware
  • Components used in seismic restraint systems

The brace member connecting the building-attached and pipe-attached components is used during applicable testing but is not itself within the principal component scope of FM 1950.

FM 1950 is associated with the FM Approvals product certification program. Laboratory testing can provide supporting performance data, but testing by an independent laboratory does not automatically grant FM Approval.

Understanding Seismic Sway Bracing

Seismic sway braces help restrain piping systems against lateral and longitudinal movement caused by earthquake forces.

During an earthquake, building structures and installed piping may experience different accelerations and displacements.

Without appropriate restraint, piping systems may be subjected to excessive movement, impact, joint damage, or failure of supporting components.

A seismic sway brace assembly generally transfers loads through a combination of:

  • A connection to the supported pipe, tubing, or conduit
  • A rigid brace member
  • A connection to the building structure
  • Appropriate fasteners and supporting structural elements

Each component must be suitable for the intended load path and installation configuration.

FM 1950 Mechanical Performance Testing

FM 1950 evaluates the mechanical performance of seismic sway brace components under specified loading conditions.

The applicable evaluation depends on the component type, intended application, and referenced edition.

Load Capacity Testing

Mechanical load testing evaluates the ability of sway brace components to resist specified forces.

Testing may determine the load at which a component experiences excessive deformation, loss of load-carrying capability, or failure.

These results can support the establishment of allowable load ratings under the standard's prescribed procedures.

Deformation Evaluation

Sway brace components must resist seismic loading without unacceptable deformation.

Laboratory measurements may document displacement and deformation as load is applied.

Deformation limits are important because excessive movement may compromise the intended restraint function even when a component has not fractured.

Connection and Attachment Testing

The performance of building-attached and piping-attached components depends on their geometry, materials, and connection arrangements.

Testing may evaluate representative assemblies and attachment configurations specified by the applicable standard.

Failure Mode Documentation

Mechanical testing can provide information about how components behave under increasing loads.

Observations may include:

  • Permanent deformation
  • Slippage or connection movement
  • Fastener or fitting damage
  • Loss of structural integrity
  • Fracture or other component failure

Documenting failure modes helps manufacturers understand the performance limitations of their designs.

FM 1950 Testing and Load Ratings

FM 1950 establishes requirements for evaluating the capacity of seismic sway brace components.

The applicable loading direction, component configuration, deformation criteria, and rating methodology must be determined from the referenced standard edition.

A component's allowable rating is not necessarily equal to its maximum measured failure load.

The approval process considers prescribed evaluation procedures and safety factors when determining appropriate ratings.

Manufacturers should not assign FM 1950 load ratings based solely on a generic tensile or compression test without confirming the standard's specific requirements.

Applications for FM 1950 Seismic Sway Braces

FM 1950 is relevant to manufacturers and suppliers of restraint components used in:

Fire Protection Sprinkler Systems

Seismic sway braces help restrain sprinkler piping against earthquake-induced movement.

The performance of these components is particularly important where seismic protection is required for water-based fire protection systems.

Industrial Piping Systems

Industrial facilities may use rigid bracing systems to restrain piping exposed to seismic loads.

Mechanical and Building Services

Pipe and tubing restraints may be incorporated into mechanical building systems where seismic design requirements apply.

Electrical Conduit Support Systems

Seismic bracing components may be used to restrain electrical conduit in installations requiring earthquake protection.

Commercial and Industrial Construction

Seismic sway brace components may be specified for buildings and facilities where structural and nonstructural restraint systems must meet applicable design requirements.

The required component selection and installation details depend on the project design and governing codes.

Why FM 1950 Testing Matters

Earthquake movement can create significant forces within piping and restraint systems.

The performance of seismic sway braces depends on the ability of their components and connections to transfer those forces safely.

Potential failure concerns include:

  • Brace component deformation
  • Connection slippage
  • Attachment failure
  • Loss of restraint capacity
  • Excessive piping movement
  • Damage to adjacent systems
  • Compromised fire protection piping integrity

Mechanical performance testing helps manufacturers evaluate component strength and deformation characteristics under controlled conditions.

Results may support product development, design improvement, engineering verification, and preparation for applicable approval programs.

FM 1950 and Related Seismic Standards

FM 1950 is one of several standards and technical documents associated with seismic restraint and building systems.

Related references include:

  • NFPA 13: Installation requirements for automatic sprinkler systems, including seismic protection provisions where applicable.
  • ASCE 7: Minimum design loads and associated criteria for buildings and other structures.
  • FM Property Loss Prevention Data Sheet 2-8: Earthquake protection for water-based fire protection systems.
  • FM Property Loss Prevention Data Sheet 1-2: Earthquake-related property loss prevention guidance.
  • ICC-ES AC156: Shake-table seismic qualification criteria for certain nonstructural components.

These documents address different aspects of seismic design, installation, testing, and performance.

FM 1950 focuses on seismic sway brace component approval criteria, while standards such as ASCE 7 and NFPA 13 provide broader design and installation requirements.

FM 1950 Testing Support at Clark Testing

Clark Testing supports manufacturers and engineering organizations with structural testing, mechanical load evaluation, vibration testing, and seismic testing services.

Our laboratory team can review component drawings, mounting configurations, specified loading requirements, and acceptance criteria to help determine an appropriate mechanical evaluation program.

For manufacturers developing seismic sway brace products, laboratory testing can provide useful engineering information about component strength, deformation, and failure behavior.

Where FM Approval is required, the manufacturer should coordinate the applicable certification requirements directly with FM Approvals. Clark Testing can discuss supporting laboratory evaluations based on the project's requirements and available testing capabilities.

Contact Clark Testing to discuss FM 1950 seismic sway brace component testing or request a quotation for structural and mechanical testing services.