Request a Quote
Superior

Testing that Reaches the World

AS 1170.4 – Earthquake Actions and Seismic Testing Support

AS 1170.4 Seismic Qualification and Earthquake Engineering Testing

AS 1170.4 establishes requirements for determining earthquake actions on structures and their components in Australia. The standard provides engineers with a framework for considering seismic forces and structural detailing when designing buildings and other applicable structures.

Equipment manufacturers and engineering teams working on Australian construction and infrastructure projects may need to evaluate how mechanical, electrical, and other installed components respond to earthquake-related loading.

Clark Testing provides seismic simulation, vibration testing, mechanical shock testing, and structural evaluation services to support equipment manufacturers and engineering organizations developing seismic qualification programs.

What Is AS 1170.4?

AS 1170.4:2024, Structural design actions, Part 4: Earthquake actions in Australia, is published by Standards Australia.

The standard provides procedures for determining earthquake actions and general detailing requirements for structures subject to seismic loading.

Its primary objective is life safety through appropriate structural design.

AS 1170.4 is part of the broader AS/NZS 1170 series addressing structural design actions.

The 2024 edition superseded AS 1170.4:2007. Engineering teams should verify which edition applies to their project, contract, and regulatory requirements.

AS 1170.4 is primarily a design standard. It does not establish a universal shake-table test procedure or a single acceleration level applicable to all equipment.

Understanding AS 1170.4 Seismic Requirements

Earthquake loading can create forces and movements that affect structural systems and attached equipment.

Seismic design requires consideration of the structure, its location, its intended use, and the characteristics of the expected earthquake motion.

Depending on the application and governing requirements, engineering evaluations may consider:

  • Geographic seismic hazard
  • Structure importance and intended occupancy
  • Ground and site conditions
  • Structural mass and dynamic response
  • Equipment location within the structure
  • Component anchorage and support systems
  • Horizontal and vertical seismic forces
  • Structural displacement and deformation
  • Applicable performance and detailing requirements

The specific design actions and calculations must be established by the responsible engineer using the applicable standard edition.

Seismic Testing for Equipment and Components

Although AS 1170.4 primarily establishes structural design requirements, laboratory testing may support verification of equipment and components intended for seismically designed facilities.

Testing can help engineers evaluate mechanical integrity, mounting performance, and functional response under specified dynamic loading.

Seismic Shake-Table Testing

Shake-table testing subjects equipment or assemblies to controlled motion representing a defined seismic test input.

Depending on the qualification program, testing may evaluate:

  • Equipment structural integrity
  • Anchorage and mounting performance
  • Dynamic response and resonance
  • Component movement and displacement
  • Mechanical connections and supports
  • Equipment functionality during or after excitation

The required test input must be developed from applicable engineering criteria and project requirements.

Vibration and Resonance Evaluation

Vibration testing can help identify resonant frequencies and evaluate equipment response to dynamic excitation.

This information may support engineering assessments of seismic susceptibility and mounting system behavior.

Mechanical Shock Testing

Mechanical shock testing may provide additional information about equipment response to transient loading where required by a separate specification.

Shock testing is not automatically equivalent to seismic qualification under AS 1170.4.

Structural and Anchorage Evaluation

Structural testing may help evaluate the performance of equipment supports, mounting assemblies, brackets, and other components subjected to specified loads.

Laboratory results can support, but do not replace, the required structural engineering calculations.

Applications for AS 1170.4 Seismic Evaluation

Seismic engineering and supporting equipment testing may be relevant to a range of Australian construction and infrastructure applications.

Electrical and Power Distribution Equipment

Electrical cabinets, control panels, switchgear, and other installed equipment may require evaluation of their seismic restraint and structural performance.

Mechanical and HVAC Equipment

Pumps, fans, compressors, HVAC units, and mechanical assemblies can impose loads on their supports and building connections during earthquake motion.

Industrial Control Systems

Control cabinets, instrumentation assemblies, and equipment racks may need to remain securely mounted under specified seismic conditions.

Emergency and Life Safety Systems

Certain emergency power, fire protection, communications, and other safety-related equipment may be subject to project-specific seismic requirements.

Building Services and Infrastructure Equipment

Piping supports, equipment frames, mounting assemblies, and other installed components may require seismic design consideration.

The applicable obligations depend on the project, equipment classification, and governing design requirements.

Why Seismic Qualification Matters

Earthquake motion can produce dynamic forces that differ significantly from normal equipment operating loads.

Equipment that performs adequately during everyday service may experience additional stresses during seismic events.

Potential concerns include:

  • Failure of mounting connections
  • Excessive equipment displacement
  • Structural deformation
  • Component detachment
  • Resonance amplification
  • Damage to electrical or mechanical connections
  • Loss of required equipment functionality

Seismic design and supporting testing can help engineers evaluate these risks and identify appropriate equipment restraints, structural supports, and qualification requirements.

Testing should be based on defined acceptance criteria rather than a generic claim of earthquake resistance.

Developing an AS 1170.4 Seismic Qualification Program

A project-specific qualification program begins with an engineering review of the equipment and its intended installation.

The process may include:

  1. Review project requirements. Identify the applicable AS 1170.4 edition, equipment classification, and governing specifications.
  2. Establish seismic design criteria. Determine the relevant forces, response characteristics, and acceptance requirements through engineering analysis.
  3. Review equipment configuration. Evaluate mass, center of gravity, mounting locations, and installation conditions.
  4. Develop the test approach. Determine whether shake-table, vibration, structural, or other laboratory testing can support the engineering objectives.
  5. Prepare mounting fixtures. Configure the specimen and supports to represent the intended installation as required.
  6. Perform testing. Apply the approved test inputs and monitor equipment response.
  7. Document results. Record test conditions, observations, measured responses, and results against the specified criteria.

The responsible design engineer or approving authority determines how laboratory evidence contributes to overall project compliance.

AS 1170.4 and Related Seismic Standards

AS 1170.4 is part of a broader group of standards and qualification methods used in structural and equipment seismic engineering.

Related standards and methods may include:

  • AS/NZS 1170.0: Structural design actions – General principles.
  • AS/NZS 1170.1: Structural design actions – Permanent, imposed and other actions.
  • AS/NZS 1170.2: Structural design actions – Wind actions.
  • ICC-ES AC156: Acceptance criteria for seismic certification by shake-table testing of nonstructural components.
  • IEEE 693: Recommended practice for seismic design of substations.
  • IEC 60068-2-57: Environmental testing using time-history vibration methods.

These documents have different purposes and are not interchangeable.

For example, AC156 provides a shake-table qualification approach for certain nonstructural components, while AS 1170.4 establishes Australian earthquake design actions.

The appropriate combination of design analysis and laboratory testing depends on the project specification.

AS 1170.4 Seismic Testing Support at Clark Testing

Clark Testing supports manufacturers and engineering organizations with seismic simulation, vibration testing, mechanical shock testing, and structural evaluation services.

Our laboratory team can review equipment configurations, mounting arrangements, engineering specifications, dynamic loading requirements, and proposed acceptance criteria to help develop a suitable testing program.

For equipment intended for Australian facilities, laboratory testing may provide supporting evidence for seismic engineering assessments based on AS 1170.4.

Whether evaluating electrical equipment, mechanical assemblies, industrial controls, or structural components, Clark Testing can assist with test planning, laboratory evaluation, and technical documentation.

Contact Clark Testing to discuss AS 1170.4 seismic qualification support or request a quotation for earthquake simulation and structural testing services.